Signs
The piece you are making

Signs people can read from where they are standing

Size the letters on a sign from the distance it will be read, know which signs the ADA Standards govern and which they do not, and put one up without breaking a local rule.

Start here Essentials

Four steps. The first and the last are done with your feet and your voice, and they are the two that matter.

  1. Pace off the distance from where a reader will stand to where the sign will be. (pacing the distance).
  2. Work out the cap height for that distance. Letter height from distance does the arithmetic (working out the cap height).
  3. Put one message on the sign, and an arrow if it points somewhere. (one message).
  4. Stand at the distance and read it out loud. (reading it out loud).

Minimum time: about 45 minutes, most of it outdoors. Done when: you read your own sign out loud, correctly, from the distance you paced, without leaning in.

Caution

Work from the ground. This manual does not teach working at height, and nothing on a sign is worth a ladder. Do not attach anything to a utility pole, a traffic sign, a street light or a tree you do not own. Never stand in a roadway to put a sign up or take one down, and do not place a sign where it blocks a driver's or a pedestrian's view of traffic, a crosswalk, a driveway or another sign.

1. What this table is, and what it is not Understand

There is one published table in the United States that connects letter height to viewing distance, and this manual uses it. It is Table 703.5.5 of the 2010 ADA Standards for Accessible Design, published by the U.S. Access Board.

Its rate, for characters mounted 40 to 70 inches above the floor, is: 5/8 inch of capital height up to 6 feet of viewing distance, plus 1/8 inch for every further foot.

Limits

The 2010 ADA Standards apply to signs in buildings and facilities covered by the Americans with Disabilities Act. They are not a general legibility rule, and a yard sale sign is not required to comply with them. Where this manual applies that rate to a flyer, a yard sign or a slide, it is borrowing a published rate and says so in the same sentence. It is doing that because it is the only published figure it found, and because an arithmetic rate from a standards body is a better starting point than somebody's guess. No standard this manual found sets a minimum letter height for a yard sign, a flyer or a slide.

The misreading runs in two opposite directions and both are worth naming:

  • "My yard sale sign has to comply with the ADA." It does not. The Standards cover signs in the scope of the law, in buildings and facilities it applies to.
  • "This table tells me how big any letter needs to be." It does not. It is a minimum for a particular kind of sign, under conditions the Standards describe, for readers standing still at a stated distance in reasonable light.

What it is good for is the thing in between: a defensible number, from a published source, that you can start from and then test by standing at the distance and reading. The number is the hypothesis; the reading is the experiment.

Ask the authority If your sign is in a building or facility covered by the ADA, section 703 governs more than height: finish, contrast polarity, character forms, stroke, spacing, line spacing, mounting location and clear floor space. Those are legal requirements, this manual quotes them so you can read them, and a code official is who certifies anything.

2. Pacing the distance, and what else changes with speed

Go to the place. Stand where a reader will be. Walk to where the sign will be, counting your steps. An adult pace is roughly two and a half to three feet, so steps times three is a usable figure.

What the Standards mean by viewing distance is useful even outside their scope: the horizontal distance between the character and whatever stops a reader from getting closer. Regulation On a sign behind a counter, that is the counter. On a sign across a road, it is the far curb.

Speed changes the problem in a way distance alone does not capture:

ReaderTypical distanceTime to readWhat the sign can carry
Standing at a counter or a door3 to 6 ftAs long as they wantSeveral lines
Walking down a corridor10 to 25 ftA few secondsOne line and an arrow
Driving at 25 miles an hour50 to 80 ft of approachRoughly a second and a halfOne word and an arrow
Driving faster than thatMoreLessOutside what this manual teaches

Preference Those reading times are arithmetic from speed and distance plus an estimate of how much of the approach a driver can spend looking at a sign; they are this manual's figures rather than a published standard. What is not an estimate is the direction of the effect: the faster a reader is moving, the less the sign can say, and the usual error is to add a line rather than to take one away.

3. Working out the cap height

Put the paced distance into Letter height from distance. It applies the published rate and tells you which row of the table the answer came from.

Viewing distanceMinimum capital height at the published rate
6 ft5/8 in
10 ft1-1/8 in
15 ft1-3/4 in
25 ft3 in
40 ft4-7/8 in
60 ft7-3/8 in

Now the part people skip. Cap height is not type size. A capital letter is shorter than the point size it is set at, because the point size measures the space the letters sit in rather than the letters themselves, and how much shorter differs by typeface. Physical principle

So the procedure is not "set it at 220 point". It is:

  1. Set one capital letter at a guess.
  2. Print it at the size it will actually be printed.
  3. Measure the letter with a ruler, from the baseline to the top.
  4. Adjust and repeat until the measurement matches the figure, then write down the point size that produced it.

Two prints usually gets you there, and the point size you write down works for every sign you make in that typeface at that size.

Test it A sign bigger than your printer is built from pieces. Print the word across several sheets in landscape, line them up on the board with a ruler, and tape or glue them down. It is crude and it reads from sixty feet, which is the only criterion the sign has.

4. One message, and an arrow if it points somewhere

At the sizes the arithmetic produces, a sign holds very little. Sixty feet gives 7-3/8 inches of capital height, and one word at that height is most of a 12 by 18 inch board. That is the finding, not a constraint to design around: anything you add comes out of the size of the thing that matters.

So the content of a sign is decided by subtraction:

  1. What is the one thing a reader has to know here? Usually a name or a direction.
  2. Does it point somewhere? Then an arrow, which is faster to read than a word.
  3. Is there anything else? If there is, ask whether it belongs on the next sign in the sequence, or on the piece at the destination.

Wendell's corner signs carry SALE and an arrow. The date, the hours and the address go on the fence sign at the house, where a reader is standing still. Yusra's hallway signs carry a room name and an arrow at each decision point, and the times go on the flyer. In both cases the sign that tried to carry everything was the sign nobody could read.

Arrows. Three habits: one arrow style for one meaning on a given sign; the arrow starting at the thing it refers to rather than floating near it; and, on a sign people walk past, the arrow pointing in the direction a person physically moves rather than at a destination on a notional map. An arrow pointing up means "straight ahead" to most readers and "upstairs" to some, which is a good reason to put it beside a staircase and not in a corridor.

A piece of trivia with a use: the Copyright Office's Circular 33 lists arrows and other directional symbols among the familiar symbols that are not copyrightable. Regulation Nobody owns an arrow.

5. Reading it out loud from the distance

Print or make the sign. Put it where it will be. Walk to the distance you paced. Turn round. Read it out loud.

Reading aloud rather than silently matters, because silent reading lets you fill in what you already know. Your mouth will not commit to a word your eye has not actually resolved.

Four things this test finds that nothing else does:

  • The letters are too small, usually because the point size was set rather than the cap height measured.
  • The contrast fails in the real light. A sign that measured fine indoors can be washed out by afternoon sun. Contrast and color has the measurement and its limits.
  • Something is in the way. A parked truck, a branch, a pole, another sign.
  • The sign faces the wrong way. Traffic approaches from one side and the sign is angled for the other.

Write what you could and could not read in the Distance test log on Before it goes out. For a sign read from a car, have somebody drive you past at the real speed, which is the only way to find out whether a second and a half is enough.

6. Putting it up

Caution

Permits and local rules. Many towns limit temporary signs by size, number, placement and how long they may stay up, and some require a permit. This manual names no rule for any place. Ask your municipal clerk or code office before you post. And get the owner's permission before you put anything on a window, a wall, a fence, a board or a lawn, and take it down when you said you would.

With those settled, the practical part:

  • Height. For a sign people read standing, somewhere around eye level is the usual choice. For reference, the ADA Standards require the baseline of a tactile character on a permanent building sign to sit between 48 and 60 inches above the floor, and visual characters at least 40 inches above the floor. Regulation Those apply in their own scope, and the 48-to-60 band is a reasonable thing to borrow for a sign a person stands in front of.
  • Angle. A sign square to the direction of approach is read sooner than one flat against a wall people walk along. For a corridor, a sign projecting from the wall is read from much further than one parallel to it.
  • Fixings. Zip ties to your own fence, tape to your own window, a stake in your own lawn. Anything that needs a drill, a ladder or somebody else's property needs their yes first.
  • Taking it down. Put the take-down date on your own calendar when you put the sign up. A sign left up past its event is the thing that gets temporary signs banned.

Table 703.5.5 in full, and the rest of section 703 Go deeper

The whole table, as published, organized by how high the characters are mounted above the floor:

Height of characters above the floorHorizontal viewing distanceMinimum character height
40 in to 70 in inclusiveLess than 72 in5/8 in
40 in to 70 in inclusive72 in and greater5/8 in, plus 1/8 in per foot of viewing distance above 72 in
Greater than 70 in to 120 in inclusiveLess than 180 in2 in
Greater than 70 in to 120 in inclusive180 in and greater2 in, plus 1/8 in per foot of viewing distance above 180 in
Greater than 120 inLess than 21 ft3 in
Greater than 120 in21 ft and greater3 in, plus 1/8 in per foot of viewing distance above 21 ft

Three things about the structure are worth noticing. The rate above the threshold is the same in every band, 1/8 inch a foot. The starting figure rises with mounting height, which is why a sign high on a wall starts at 2 inches and one above 10 feet starts at 3. And character height is measured on an uppercase I, from its baseline to its top.

The rest of section 703, for signs in its scope:

  • Visual characters (703.5): non-glare finish, light characters on a dark background or dark on light; uppercase, lowercase or both; forms conventional in form, not italic, oblique, script, highly decorative or unusual; the width of an uppercase O between 55 and 110 percent of the height of an uppercase I; at least 40 inches above the floor.
  • Raised (tactile) characters (703.2): raised at least 1/32 inch; uppercase only; sans serif, not italic, oblique, script, highly decorative or unusual; between 5/8 inch and 2 inches high.
  • Braille (703.3): duplicates the raised characters, at least 3/8 inch below the text.
  • Installation (703.4): the lowest tactile baseline at least 48 inches above the floor, the highest at most 60 inches. At a door, the sign goes on the latch side; on the inactive leaf of double doors with one active leaf; to the right of the right-hand door where both leaves are active; and on the nearest adjacent wall where there is no latch-side wall space. Clear floor space of at least 18 by 18 inches, centered on the tactile characters and outside the arc of a door swinging from closed to 45 degrees.
  • Pictograms (703.6): a field at least 6 inches high with no characters or braille inside it, and a text descriptor directly below the field.

Two of those are worth borrowing outside their scope: a text descriptor under any pictogram, and a non-glare finish on anything laminated.

Stroke, spacing and what a condensed face does Go deeper

Section 703.5 states stroke and spacing as percentages of character height rather than as absolute figures, which makes them portable to any size.

MeasureRangeWhat it means at a 3 in capital
Stroke thickness10 to 30 percent of character height0.3 to 0.9 in
Character spacing10 to 35 percent of character height, between the two closest points of adjacent characters, excluding word spaces0.3 to 1.05 in
Line spacing135 to 170 percent of character height4.05 to 5.1 in
Width of an uppercase O55 to 110 percent of the height of an uppercase I1.65 to 3.3 in wide

Regulation Those are the figures for signs in the scope of the Standards. Outside that scope they are a useful sanity check on a typeface, and the fourth row is the one that catches a condensed face.

What a condensed face does. A condensed typeface is narrower for a given height, which is exactly what somebody reaching for when a word will not fit. Narrowing the letters narrows the counters, the enclosed white spaces inside letters like o, e and a, and those counters are part of how a reader tells one letter from another at a distance. Section 703.5.4's 55-percent floor on the width of an O relative to an I is a standards body writing that down.

So when a word does not fit, the better moves in order are: use fewer words; use a shorter word; make the sign bigger; and only then condense, and check the O width against the I height if you do.

Weight. A very light weight loses at a distance for the same reason: the stroke becomes thin relative to the character and the letter starts to break up in glare and in the rain. The 10-percent floor on stroke thickness is the published version of that.

A sequence of signs Go deeper

One sign rarely gets somebody anywhere. What works is a sequence, where each sign answers the question the last one raised.

The way to design it is not to make a map and place signs on it. It is to walk the route as a stranger and stop at every point where you would have to decide something. Those points are your signs. One per decision; no sign where there is no decision.

A route from a library's front door to a room upstairs might be:

  1. At the front door: the name of the thing and an arrow. "Story Hour, Oak Room" with an arrow. The question this raises is "which way next".
  2. At the point where the corridor branches: an arrow up the stairs. It answers the last question and raises "how will I know the room".
  3. At the top of the stairs or on the door: "Oak Room". It answers the question and raises none.

Two rules that make a sequence work:

  • Use the same words throughout. If the first sign says Oak Room, the last one says Oak Room, not Room 2B and not Children's Room. A reader is pattern-matching a string, and changing the words breaks the chain.
  • Use the same look throughout. Same typeface, same color, same shape of board. A reader learns in two signs what your signs look like, and then finds the third one faster.

The test is to give the route to somebody who has not walked it and follow them. The place where they stop and look up is the place that needs a sign; the place where they walk past a sign without seeing it is a sign in the wrong position.

The ADA title II web rule, which is not about your sign Go deeper

One thing worth knowing if you are making signs for a town, a public library, a public school district or a county office, because it comes up in the same conversations and is about something else entirely.

The Department of Justice published a rule on the accessibility of web content and mobile apps provided by state and local governments. Its technical standard is WCAG 2.1, Level AA. Regulation It applies to the body's website and mobile apps, not to its printed signs.

The compliance dates moved. On April 20, 2026 the Federal Register published an interim final rule extending them to April 26, 2027 for entities serving a population of 50,000 or more, and April 26, 2028 for entities serving fewer than 50,000 and for any special district government. Those dates were live when this manual was built and should be re-checked rather than relied on from here.

A related mismatch worth knowing about, because it confuses people who work for public bodies: the Revised 508 Standards, which govern federal electronic content, still incorporate WCAG 2.0 by reference, while this title II rule requires WCAG 2.1 Level AA. Two federal rules, two versions of the same guidelines.

And one more, from the W3C itself: WCAG 2.2 does not deprecate or supersede WCAG 2.1, and 2.0, 2.1 and 2.2 are all existing standards. The contrast criteria this manual uses, 1.4.3 and 1.4.6, are unchanged between 2.1 and 2.2.

7. See it: a corner, a lot entrance and a hallway See it

Fictional example

Wendell Halvorsen's corner signs. Saturday, 8:00 AM to 2:00 PM, 1409 Vance Street. Two signs on posts at the corners of Vance and Pell, read from a car at about twenty-five miles an hour with roughly sixty feet of warning, which he paced along the curb. 12 by 18 inch posterboard, made in Microsoft Word, printed at home on letter paper and taped to board.

Known. Sixty feet of approach. One decision for the driver: turn onto Vance or not.

Assumed. That a driver is looking for the sign. They are not. Test it Wendell settles it by having a neighbor drive him past at the real speed.

Open. Whether a sign may stand at that corner and for how long. Settled by: his municipal clerk, whom he calls before making anything.

The arithmetic. Sixty feet at the published rate is 5/8 inch plus 1/8 inch for each of the 54 feet over six, which is 7-3/8 inches of capital height. His board is 12 by 18 inches. One word at 7-3/8 inches tall occupies most of it.

What that decided. The corner signs carry SALE and an arrow, and nothing else, because nothing else fits at a size a driver can read. The date, the hours and the street number go on the fence sign at the house, which is read by somebody who has already turned and slowed down. Under these assumptions, that split works; the fact that would change it is whether drivers actually slow at the corner, which the drive-past tells him.

What the drive-past found. The first placement put the sign where a parked van blocked it for the last twenty feet of the approach. Twenty feet closer to the corner and in front of the van's usual spot fixed it. No amount of arithmetic would have found that.

Fictional example

Dolores Reyes's lot entrance signs and sandwich board. Two 18 by 24 inch signs on corrugated board at the Arbor Street lot entrance, read from a slow-moving car at about forty feet; one sandwich board at the lot gate read at about fifteen feet. Signs at a sign shop.

Known. Forty feet gives 4-7/8 inches of capital height at the published rate; fifteen feet gives 1-3/4 inches.

Assumed. That cars entering are already slowing. Dolores's assumption, and a reasonable one at a lot entrance, which is why forty feet rather than sixty.

Open. Whether the municipality allows a sandwich board at the gate. Settled by: the clerk.

The two signs are doing different jobs. The entrance signs carry MARKET and an arrow at 4-7/8 inches, which fits comfortably on an 18 by 24 inch board. The sandwich board, read at fifteen feet by somebody on foot who has already arrived, carries the name at 1-3/4 inches, the hours beneath it, and a line about where to pay for parking. Three times as much content, because the distance is a third.

The sign shop asks for a print-ready file. The resolution target for large format is 150 PPI at the finished size, so an 18 by 24 inch sign wants about 2700 by 3600 pixels for anything placed full size. Page setup and resolution does that arithmetic, and the type is vector rather than pixels so it is unaffected.

Fictional example

Yusra Ahmadi's hallway signs. A sequence of three inside the Pennebaker Branch Library so that families find the Oak Room. Many of the adults bringing children are grandparents, so large type is a requirement rather than a preference. She works in Google Docs.

Known. She watched for ten minutes at 10:15 on a Thursday and found three decision points: the front door, the branch in the corridor, and the top of the four steps. The corridor sign is read at about twenty-five feet, which gives 3 inches of capital height.

Assumed. That people start at the front door. She found by watching that some come in from the side, which is why there are three signs and not two.

Open. Whether a sign may be fixed to the wall at the stairs. Settled by: the branch manager.

The audience changes one thing. The published rate is a minimum for readers in general. Knowing that many of her readers are older, Yusra sizes above it rather than at it, which is a decision the rate supports rather than one it makes. Every sign says Oak Room, in those words, in the same typeface. Nothing says Room 2B.

This is also the one place in this manual where the ADA title II web rule is relevant, and it is not relevant to the signs: the branch belongs to a county library system, so the system's website is in scope of that rule, with compliance dates in April 2027 or April 2028 depending on the population it serves. The hallway signs are governed by the building's own obligations under the 2010 Standards, where those apply, and the branch's facilities staff are who know.

8. Practice: one letter, one distance, one reading Practice

Minimum: one paced distance, one letter measured against the figure, and one reading out loud from the distance. That is the result Start here asks for. Time: about 45 minutes, most of it at the site. Materials: a ruler, a printer, tape or a board, and the place.

  1. Call the clerk first if the sign is going anywhere public. It takes five minutes and it decides whether the rest is worth doing.
  2. Pace the distance from where the reader will be to where the sign will be, and write the number in feet.
  3. Get the cap height from Letter height from distance.
  4. Set one capital letter, print it, measure it with a ruler, and adjust until the measurement matches. Write down the point size that produced it.
  5. Write the sign's one message. If it is more than three or four words, ask what belongs on the next sign instead.
  6. Make it, put it where it will be, walk to the distance, and read it out loud.
  7. For a sign read from a car, be driven past at the real speed.
  8. Write the result in the Distance test log on Before it goes out, and put the take-down date in your calendar.
Go deeper

The time-of-day check. Look at the sign at the hour people will actually be arriving. Low sun across a sign is a different object from the same sign at noon, and a laminated one at the wrong angle is a mirror.

The stranger walk. Give somebody the destination and follow them without speaking. Where they stop is where a sign is missing; where they walk past yours is where one is in the wrong place.

The condensed check. If you have condensed the type to fit a word, print a capital O and a capital I at the same size and measure both. If the O is narrower than about 55 percent of the I's height, you have gone past where a standards body would.

9. Your piece Your piece

10. Check your work Check your work

Criteria

  • Did the distance come from pacing rather than from estimating?
  • Was the letter height measured with a ruler on a print, rather than set as a point size?
  • Can you read the sign out loud from the distance, without leaning in?
  • Does the sign carry one message, with the rest moved to the next sign or the destination?
  • Have you asked whoever owns the place, and the clerk if it is anywhere public, and set a take-down date?

Worked example

Wendell's corner signs pass every criterion, and the arithmetic is what made them pass: 7-3/8 inches of capital height on a 12 by 18 inch board forces one word, so an address line was not an option. He called the clerk first. The criterion the first placement failed was the third, because of a parked van, and the drive-past is what found it. Yusra's sequence passes the fourth criterion by construction, because each sign was placed at a decision point rather than at a convenient wall.

Common mistakes

  • Setting a point size instead of measuring a cap height. The relationship differs by typeface, and the error is usually in the direction of too small.
  • Estimating the distance from a window. Pace it.
  • Adding a line. Everything you add comes out of the size of what matters.
  • Condensing the type to make a word fit. Fewer words first; a bigger sign second.
  • Treating Table 703.5.5 as a requirement for a yard sign, or as a general legibility law.
  • Laminating with a gloss finish. It adds a reflection; matte avoids most of it.
  • Putting it up without asking.
  • Leaving it up afterward.

What is still unresolved

This chapter names no local rule and cannot. Sign ordinances, permits and posting rules vary by town and sometimes by street, and the municipal clerk or code office is who answers. It does not design life-safety signage: exits, fire equipment markings, hazard warnings and emergency instructions are governed by codes and standards, and the fire marshal or building official is who answers those. It does not certify anything under the ADA; where the law applies to a building, its sign requirements are legal requirements that a code official settles. It teaches no work at height and no mounting to anything you do not own. And the contrast side of a readable sign is Contrast and color, including the Standards' own requirement for a non-glare finish and for light characters on dark or dark on light.

11. Knowledge check and scenario

A reader asks whether their yard sale sign has to meet the ADA letter-height table. What is the answer?
No. The 2010 ADA Standards apply to signs in buildings and facilities covered by the Americans with Disabilities Act. This manual borrows Table 703.5.5's rate, 5/8 inch at six feet plus 1/8 inch per further foot, as a published sizing rate for other pieces, and says that is what it is doing. No standard this manual found sets a minimum letter height for a yard sign.
Why is "set the headline at 220 point" the wrong instruction for a sign?
Because point size is not letter height. The point size measures the space the letters sit in, and a capital letter is shorter than it by an amount that differs between typefaces. The instruction that works is to set one capital letter, print it at the real size, measure it with a ruler against the figure, adjust, and then write down the point size that produced the right measurement.
You have sixty feet of approach and three things to say. What does the arithmetic tell you to do?
Sixty feet gives 7-3/8 inches of capital height at the published rate, and one word at that height fills most of an ordinary board. So the sign carries one message, and the other two things go on the next sign in the sequence or on the piece at the destination, where the reader has stopped. Adding a line costs the size of the line that matters.
(Go deeper) Why does a condensed typeface lose at a distance?
Because narrowing the letters narrows their counters, the enclosed white shapes inside letters like o, e and a, and those shapes are part of how a reader tells one letter from another at a distance. The ADA Standards put a floor under it: the width of an uppercase O has to be at least 55 percent of the height of an uppercase I. When a word will not fit, use fewer words, a shorter word, or a bigger sign before you condense.
You need a sign so people walking down a 25-foot corridor can find a meeting room. You have an 8.5 by 11 inch sheet and a printer, and you want to put the room name, the meeting name and the time on it.
Twenty-five feet gives 3 inches of capital height at the published rate. Three lines at 3 inches each, with the line spacing the Standards describe, is more than an 8.5 by 11 inch sheet holds, so fitting all three means setting them all smaller than the figure, and then none of them reads from the corridor.
This is the subtraction the arithmetic forces, and it is also the better sign. The corridor reader has one question, which is which door, and the answer is a room name and an arrow. The meeting name and the time are read by somebody standing at the door, where a sheet at arm's length holds far more.
A real option if you have access to the larger sheet, and it buys you roughly twice the area. The thing to check is whether the second and third lines are doing any work at 25 feet; usually a reader at that distance is only choosing a door, and the extra lines are read at the door anyway.

Checklist

Records your learning only; it is not a qualification.